. 2017, (06): 0-0.
Abstract:Different media; Error;Repeatability Ultrasonic gas flowmeter are widely used in various industries because of Good ,Loss of pressure is small, high precision and wide measurement range. Especially because of its good stability, high measuring accuracy become a preferred gas trade transition flow measuring instruments. Most of the ultrasonic flowmeter test using the negative pressure method, the atmospheric state with air as medium to test, with the ultrasonic flowmeter in actual usage (high pressure, measuring medium for natural gas). Based on the DN100, contact type ultrasonic flowmeter with positive pressure, medium for natural gas and negative pressure, medium for air condition to analyze the error of the meter from different condition and stability. Concluded negative pressure, measuring medium for natural gas and boundary flow above, flowmeter relative error and repeatability decreased gradually along with the change of flow point, and after a threshold leveled off is change, above negative pressure air calibration condition, boundary flow meter relative error and repeatability value along with the change of flow point appears irregular change,Under flow boundary points are compaction flow state and negative pressure air calibration error and repeatability are showed irregular change.